Accurately measures power consumption and calculates the operating costs of electronic devices.
Accurately measures power consumption and calculates the operating costs of electronic devices.
The T1500 is an easy-to-use power meter that accurately measures the power consumption of electronic devices. Simply set the local utility rate in Kilowatt-hours (KWH) and connect an appliance to start tracking cost. The T1500 can also be used to verify power quality by monitoring voltage, frequency, and power factor.
Key Features
Applications
| Measuring Ranges | Voltage: 100 to 150VAC 60Hz Current: 0 to 15A Power: 0 to 1800W Power Factor: 0 to 1.00 Frequency: 45 to 65Hz |
| Accuracy | Voltage: ±(1% rdg. + 1 dgt.) Current: ±(1% rdg. + 10 dgt.) at 0.010 to 0.999A; ±(1% rdg.+ 5 dgt.) at 1.00 to 15.00A Power: ±(1% rdg. + 10 dgt.) at 1.0 to 100.0W; ±(1% rdg. + 5 dgt.) at 100.0 to 999.9W; ±(1% rdg. + 1 dgt.) at 1000 to 1800W Power Factor: ±(2% rdg. + 10 dgt.) at 0.30 to 0.49; ±(2% rdg. + 5 dgt.) at 0.50 to 1 Frequency: ±(1% rdg. + 1 dgt.) |
| Logging Ranges | Energy: 0 to 9999kWh Cost: $0 to 9999 Total Time: 0 minutes to 9999 days |
| Display | Dual LCD |
| Display Update | 1 time/second |
| Overrange Indicator | Yes |
| Power Supply | 1 x 3V Battery (CR2032, back up battery) |
| Overvoltage Category | CAT II 150V |
| Product Certifications | CE, ETL, Conforms to UL STD.61010-1, 61010-2-030; Certified to CSA STD.C22.2 NO.61010-1, 61010-2-030 |
| Operating Temperature | 32 to 122°F (0 to 50°C) |
| Storage Temperature | 14 to 140°F (-10 to 60°C) |
| Operating Humidity Range | 10 to 90% |
| Dimensions | 5.1 x 2.6 x 1.5" (130 x 65 x 37mm) |
| Weight | 1.9oz (155g) |
| Measuring Ranges | Voltage: 100 to 150VAC 60Hz Current: 0 to 15A Power: 0 to 1800W Power Factor: 0 to 1.00 Frequency: 45 to 65Hz |
| Accuracy | Voltage: ±(1% rdg. + 1 dgt.) Current: ±(1% rdg. + 10 dgt.) at 0.010 to 0.999A; ±(1% rdg.+ 5 dgt.) at 1.00 to 15.00A Power: ±(1% rdg. + 10 dgt.) at 1.0 to 100.0W; ±(1% rdg. + 5 dgt.) at 100.0 to 999.9W; ±(1% rdg. + 1 dgt.) at 1000 to 1800W Power Factor: ±(2% rdg. + 10 dgt.) at 0.30 to 0.49; ±(2% rdg. + 5 dgt.) at 0.50 to 1 Frequency: ±(1% rdg. + 1 dgt.) |
| Logging Ranges | Energy: 0 to 9999kWh Cost: $0 to 9999 Total Time: 0 minutes to 9999 days |
| Display | Dual LCD |
| Display Update | 1 time/second |
| Overrange Indicator | Yes |
| Power Supply | 1 x 3V Battery (CR2032, back up battery) |
| Overvoltage Category | CAT II 150V |
| Product Certifications | CE, ETL, Conforms to UL STD.61010-1, 61010-2-030; Certified to CSA STD.C22.2 NO.61010-1, 61010-2-030 |
| Operating Temperature | 32 to 122°F (0 to 50°C) |
| Storage Temperature | 14 to 140°F (-10 to 60°C) |
| Operating Humidity Range | 10 to 90% |
| Dimensions | 5.1 x 2.6 x 1.5" (130 x 65 x 37mm) |
| Weight | 1.9oz (155g) |